Supported mixers

Mixer Status
Behringer X Air (XR18, XR16) Supported. Tested on an XR18 with firmware 1.20.
Behringer XR12, Midas MR18 Accepted, not tested.
Mackie DL32S Supported.
Behringer X32, Midas M32 In testing. Built from the published protocol and an emulator, not yet tried on a real desk.
Behringer WING In testing. Built from Behringer’s protocol document, not yet tried on a real desk.
Mackie DL16S, DL32R Not supported. The app refuses to connect.

If you try OpenFader with a mixer marked “in testing”, try it with Work offline first, then on the real desk before a service or show, not during one. Reports from real desks help: use Report a bug in Settings.

What works on every supported mixer

Faders, mute, solo, pan, meters, channel names, gain, gate, compressor, EQ and sends. Each mixer uses its own fader scale, so the dB values in OpenFader match the desk.

Controls the mixer does not have are hidden or greyed out, with the reason shown. OpenFader never shows a control it cannot actually send to the mixer.

What differs

X Air DL32S X32 / M32 WING
Effects slots 4 4 8 16
Effects on / bypass No No No No
Input routing Yes Yes Yes Yes
Output routing Yes Yes Yes No
Mixer’s own scenes 64 snapshot slots Stored show, Show.zip files Scenes, snippets, cues, presets No
Automatic virtual soundcheck XR18 firmware 1.20 only No No No

“Effects on / bypass: No” means OpenFader cannot switch a whole effects slot on or off yet. You can still change the effect and its settings.

Connection details

Your device and the mixer need to be on the same network and subnet. If your network blocks these ports, OpenFader cannot reach the mixer.

Mixer Port
X Air UDP 10024 (falls back to 10023)
X32 / M32 UDP 10023
WING UDP 2223 for control, TCP 2222 for meters
DL32S TCP 50001

Notes per mixer

X Air. Some setups answer on port 10023 instead of 10024. OpenFader tries both.

DL32S. Loading the mixer’s state after connecting can take up to 90 seconds. Discover mixers can miss it the first time, so add it by IP address. A few control ranges come from Mackie’s manual rather than testing.

X32 / M32. The meter analyser (RTA) is not available.

WING. Preamp controls only appear when the channel’s source is a local or AES50 input.